2.2 CIRCUIT CONNECTION

The table lists the connectors that link each component to the BICU. The
connectors CN303 through CN307 link each component to the ADF connection
board. The connectors CN302 and CN301 link the ADF connection board to the
BICU.
Component
ADF motor
Original set sensor
Original registration sensor
Guide open sensor
ADF clutch
Unit open switch

2.3 ORIGINAL DETECTION

When you set an original on the original table, the original pushes down the feeler
[A] of the original set sensor [B]. (If the copier is in Energy Saver mode, it will
automatically recover at this time.)
NOTE: The ADF does not scan the reverse side of the original. The ADF does not
detect paper sizes.
SM
CÓPIA NÃO CONTROLADA
ADF
Connection board
CN303
CN305
CN306
CN307
[B]
[A]
13
CÓPIA NÃO CONTROLADA
CIRCUIT CONNECTION
BICU
CN302
CN109
CN301
CN110
B696D900.WMF
B696