Error Code
Message Information
CPU0803
Message
LCD Message
Details
Action
CPU0804
Message
LCD Message
Details
Action
CPU0805
Message
Details
Action
CPU0806
Message
98
The power input for CPU <number> voltage regulator
module is lost.
Lost power input for CPU <number>voltage regulator
module. Re-seat module.
System performance may be degraded or the system may
fail to operate.
1.
Turn system off and remove input power for one
minute.
2.
Reapply input power and turn system on.
3.
Ensure the processor is seated correctly.
4.
If the issue persists, see
The power input for CPU <number> voltage regulator
module is outside of range.
The power input for CPU <number> voltage regulator
module is outside of range. Re-seat module.
System performance may be degraded or the system may
fail to operate.
1.
Turn system off and remove input power for one
minute.
2.
Reapply input power and turn system on.
3.
Ensure the processor is seated correctly.
4.
If the issue persists, see
The power input for CPU <number> voltage regulator
module is outside of range, but it is attached to the system.
System performance may be degraded or the system may
fail to operate.
1.
Turn system off and remove input power for one
minute.
2.
Reapply input power and turn system on.
3.
Ensure the processor is seated correctly.
4.
If the issue persists, see
CPU <number> voltage regulator module is incorrectly
configured.