Error Code
Message Information
PCI2002
Message
LCD Message
Details
Action
PCI3000
Message
Details
Action
PCI3002
Message
Details
Action
PCI3004
Message
Details
Action
PCI3006
Message
Details
Action
PCI3008
Message
Details
A fatal IO error detected on a component at slot <number>.
Fatal IO error on slot <number>.
System performance may be degraded, or system may fail to
operate.
Cycle input power, update component drivers, remove and
reinstall the device.
Device option ROM on embedded NIC failed to support Link
Tuning or FlexAddress.
Either the BIOS, BMC/iDRAC, or LOM firmware is out of date
and does not support FlexAddress.
Update BIOS, BMC/iDRAC, and LOM firmware. If the issue
persists, see
Getting
Help.
Failed to program virtual MAC address on a component at
bus <bus>device<device>function <func>.
Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of
date and does not support FlexAddress.
Update BIOS, BMC/iDRAC, LOM, and mezzanine card
firmware. If the issue persists, see
Device option ROM on mezzanine card <number> failed to
support Link Tuning or FlexAddress.
Either the BIOS, BMC/iDRAC, or mezzanine card firmware is
out of date and does not support FlexAddress.
Update BIOS, BMC/iDRAC, and mezzanine card firmware. If
the issue persists, see
Getting
Failed to get Link Tuning or FlexAddress data from iDRAC.
Either the BIOS or BMC/iDRAC firmware is out of date and
does not support FlexAddress.
Update BIOS, and BMC/iDRAC firmware. If the issue persists,
see
Getting
Help.
A non-fatal PCIe error detected on a component at bus
<bus>device<device>function <func>.
System performance may be degraded.
Getting
Help.
Help.