Advertisement

Error Code
Message Information
Details
Action
PWR1006
Message
LCD Message
Details
Action
PWR1007
Message
LCD Message
Details
Action
PWR1008
Message
LCD Message
Details
Action
RFM1003
Message
Details
Action
RFM1005
Message
Details
126
The user-defined power settings have affected system
operation.
If unintended, review system configuration changes and
power policy.
The system halted because system power exceeds capacity.
System power demand exceeds capacity. System halted.
The system halted because system power exceeds capacity.
Review system configuration, upgrade power supplies or
reduce system power consumption.
The system performance degraded because power exceeds
capacity.
System power exceeds capacity. Performance degraded.
Check PSU configuration.
The system is currently operating in a performance degraded
state to attempt protect from a power shutdown.
Review system configuration, upgrade power supplies or
reduce system power consumption.
The system performance degraded because power draw
exceeds the power threshold.
System power exceeds threshold. Performance degraded.
Check PSU configuration.
The power threshold is configured by the user or
automatically by software based on system configuration.
Review system configuration, upgrade power supplies or
reduce system power consumption.
Removable Flash Media <name> is not IPMI-function ready.
The removable flash media is installed but improperly
configured or failed to initialize.
If unintended, reinstall the flash media and module.
Removable Flash Media <name> is not ready.
The media is being prepared or is under maintenance. If the
problem persists, reinstall the card.