Error Code
Message Information
CPU0010
Message
Details
Action
CPU0023
Message
LCD Message
Action
CPU0100
Message
Details
Action
CPU0101
Message
LCD Message
Details
Action
CPU0102
Message
Details
Action
CPU0103
Message
LCD Message
Details
Action
CPU0104
Message
LCD Message
Details
CPU <number> is throttled.
The CPU is throttled due to thermal or power conditions.
Review system logs for power or thermal exceptions.
CPU <number> is absent.
CPU <number> is absent. Check CPU.
Verify processor installation. If present, re-seat the
processor.
CPU <number> temperature is less than the lower warning
threshold.
System performance may be degraded.
Check system operating environment.
CPU <number> temperature is less than the lower critical
threshold.
CPU <number> temperature is outside of range.
System performance may be degraded.
Check system operating environment, fans, and heat-sinks.
CPU <number> temperature is greater than the upper
warning threshold.
System performance may be degraded.
Check system operating environment, fans, and heat-sinks.
CPU <number> temperature is greater than the upper critical
threshold.
CPU <number> temperature is outside of range. Check fans.
System performance may be degraded.
Check system operating environment, fans, and heat-sinks.
CPU <number> temperature is outside of range.
CPU <number> temperature is outside of range. Check fans.
System performance may be degraded.
93