Advertisement

Error Code
Message Information
Details
Action
PCI1344
Message
LCD Message
Action
PCI1346
Message
Action
PCI1348
Message
LCD Message
Details
Action
PCI1350
Message
LCD Message
Details
Action
PCI1354
Message
Details
Action
System performance may be degraded, or system may fail to
operate.
Cycle input power, update component drivers, if device is
removable, reinstall the device.
An I/O channel check error was detected.
An I/O channel check error was detected. Power cycle
system.
Cycle input power, update component drivers, if device is
removable, reinstall the device.
A software error was detected on a component at slot
<number>.
Reboot the system and update the component drivers.
A PCI parity error was detected on a component at slot
<number>.
PCI parity error on slot <number>. Re-seat PCI card.
System performance may be degraded, or system may fail to
operate.
Cycle input power, update component drivers, if device is
removable, reinstall the device.
A PCI system error was detected on a component at slot
<number>.
PCI parity error on slot <number>. Re-seat PCI card.
System performance may be degraded, or system may fail to
operate.
Cycle input power, update component drivers, if device is
removable, reinstall the device.
A bus correctable error was detected on a component at slot
<number>.
System performance may be degraded.
Cycle input power, update component drivers, remove and
reinstall the device at the next scheduled service time.
113