Error Code
Message Information
VLT0102
Message
LCD Message
Details
Action
VLT0103
Message
LCD Message
Details
Action
VLT0104
Message
LCD Message
Details
Action
Processor module <name> voltage is greater than the upper
warning threshold.
Processor module <name> voltage is outside of range.
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
1.
Review system logs for power supply exceptions.
2.
Remove the processor module. Inspect processor
socket for bent pins.
3.
If the issue persists, see
Processor module <name> voltage is greater than the upper
critical threshold.
Processor module <name> voltage is outside of range.
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
1.
Review system logs for power supply exceptions.
2.
Remove the processor module. Inspect processor
socket for bent pins.
3.
If the issue persists, see
Processor module <name> voltage is outside of the
allowable range.
Processor module <name> voltage is outside of range.
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
1.
Review system logs for power supply exceptions.
2.
Remove the processor module. Inspect processor
socket for bent pins.
3.
If the issue persists, see
Getting
Help.
Getting
Help.
Getting
Help.
143