Error Code
Message Information
Details
Action
PST0134
Message
LCD Message
Details
Action
PST0135
Message
LCD Message
Details
Action
PST0136
Message
LCD Message
Details
Action
PST0137
Message
LCD Message
Details
Action
PST0138
Message
LCD Message
Details
Action
System BIOS detected a failure with the DMA controller
during system POST.
Remove and reapply input power.
Interrupt controller failed.
Interrupt controller failed. Power cycle system.
System BIOS detected a failure with the interrupt controller
during system POST.
Remove and reapply input power. If the issue persists, see
Getting
Help.
Timer refresh failed.
Timer refresh failed. Power cycle system..
System BIOS detected a timer refresh failure during system
POST.
Remove and reapply input power. If the issue persists, see
Getting
Help.
Programmable interval timer error.
Programmable interval timer error. Power cycle system.
System BIOS detected an failure with the programmable
interval timer during POST.
Remove and reapply input power. If the issue persists, see
Getting
Help.
Parity error.
Parity error. Power cycle system.
System BIOS detected a parity error during post.
Remove and reapply input power. If the issue persists, see
Getting
Help.
SuperIO failed.
SuperIO failure. Power cycle system.
System BIOS detected a failure with the SIO.
Remove and reapply input power. If the issue persists, see
Getting
Help.