Error Code
Message Information
TMP0104
Message
LCD Message
Details
Action
TMP0106
Message
LCD Message
Details
Action
TMP0107
Message
LCD Message
Details
Action
TMP0108
Message
LCD Message
Details
Action
TMP0109
Message
LCD Message
Details
Action
138
The system board <name> temperature is outside of range.
System board <name> temperature is outside of range.
Ambient air temperature is too warm or cool.
The system board <name> temperature is outside of the
optimum range. Check Fans.
The memory module <number> temperature is less than the
lower warning threshold.
Memory module <number> temperature is outside of range.
Ambient air temperature is too cool.
Check the system operating environment.
The memory module <number> temperature is less than the
lower critical threshold.
Memory module <number> temperature is outside of range.
Ambient air temperature is too cool.
Check the system operating environment.
The memory module <number> temperature is greater than
the upper warning threshold.
Memory module <number> temperature is outside of range.
Check Fans.
Ambient air temperature is too warm or one or more fans
may have failed.
The system board <name> temperature is outside of the
optimum range. Check Fans.
The memory module <number> temperature is greater than
the upper critical threshold.
Memory module <number> temperature is outside of range.
Check Fans.
Ambient air temperature is too warm or one or more fans
may have failed.
The system board <name> temperature is outside of the
optimum range. Check Fans.