Error Code
Message Information
Details
Action
BAT0019
Message
LCD Message
Details
Action
CBL0006
Message
Details
Action
CPU0000
Message
LCD Message
Details
Action
CPU0001
Message
LCD Message
Details
Action
CPU0002
Message
Action
The <name> battery is either missing, bad, or unable to
charge due to thermal issues.
Check system fans. Replace the <name> battery.
The <name> battery is absent.
The <name> battery is absent. Check battery.
The failed or missing <name> battery may reduce system
performance.
Check system fans. Replace the <name> battery.
Multiple storage controllers are incorrectly connected to the
same backplane <Bay ID>.
Unsupported backplane configuration.
Check backplane configuration. Reconnect cable. If the issue
persists, see
Getting
Help.
CPU <number> has an internal error (IERR).
CPU <number> has an internal error (IERR).
System event log and OS logs may indicate that the
exception is external to the processor.
Review System Event Log and Operating System Logs. If the
issue persists, see
Getting
CPU <number> has a thermal trip (over-temperature) event.
CPU <number> has a thermal trip. Check CPU heat sink.
The processor temperature increased beyond the
operational range.
Review logs for fan failures, replace failed fans. If no fan
failures are detected, check inlet temperature (if available)
and reinstall processor heat-sink.
CPU <number> has failed the built-in self-test (BIST).
1.
Turn system off and remove input power for one
minute. Reapply input power and turn system on.
2.
Make sure the processor is seated correctly.
3.
If the issue persists, see
Help.