Track_Data_Send_Flags Property; Termination_Char Property - Elo TouchSystems ET1229L Series User Manual

12.1" lcd touchmonior with optional magnetic stripe reader, finger print reader and rear facing customer display
Hide thumbs Also See for ET1229L Series:
Table of Contents

Advertisement

USB HID Keyboard Emulation Swipe Reader

TRACK_DATA_SEND_FLAGS PROPERTY

Property ID:
Property Type:
Length:
Get Property:
Set Property:
Default Value:
Description:
0
SS
ES
SS
0 – Don't send Start Sentinel for each track
1 – Send Start Sentinel for each track
ES
0 – Don't send End Sentinel for each track
1 – Send End Sentinel for each track
LRC
0 – Don't send LRC for each track
1 – Send LRC for each track
Note that the LRC is the unmodified LRC from the track data. To verify the LRC
the track data needs to converted back from ASCII to card data format and the
start sentinels that were modified to indicate the card encode type need to be
converted back to their original values.
LC
0 – Send card data as upper case
1 – Send card data as lower case
Note that the state of the Caps Lock key on the host keyboard has no affect on
what case the card data is transmitted in.
Er
00 – Don't send any card data if error
01 – Don't send track data if error
11 – Send 'E' for each track error
This property is stored in non-volatile EEPROM memory so it will not change when the unit is
power cycled. When this property is changed, the unit must be power cycled to have these
changes take effect. If a value other than the default value is desired, it can be set by the factory
upon request.

TERMINATION_CHAR PROPERTY

Property ID:
Property Type:
Length:
Get Property:
20
4
Byte
1 byte
Yes
Yes
63 (hex)
This property is defined as follows:
LRC
0
LC
Er
5
Byte
1 byte
Yes
Er

Advertisement