Maintenance and Troubleshooting
Troubleshooting
Table 30
Table 30
BSIA LEDs during Boot Up and Normal Operation
Bottom
Label
9
8
7
6
5
4
3
2
1
90
explains the meaning of the LED states during boot up and normal operation.
Top
Color
Label
POWER
Green
The power is on.
MASTER
Yellow
This LED should always be lit.
The test that checks the
BUSY1
Green
integrity of the connection to
Base Station 1 failed.
Loss of synchronization occurs on Base Station 1 because of poor
RLOS1
Red
connection, bad cable, Base Station or BSIA failure.
The test that checks the
BUSY2
Green
integrity of the connection to
Base Station 2 failed.
Loss of synchronization occurs on Base Station 2 because of poor
connection, bad cable, Base Station failure, BSIA failure; or the
RLOS2
Red
Second Base Station Service Enabled parameter is set to TRUE in
the System Settings database when the system has one Base
Station only.
The test that checks the
S3
Yellow
integrity of the real time clock
failed.
The test that checks the
integrity of call processing
software stored in non-volatile
S2
Yellow
memory failed. Try reloading the
software (see
Activate External Critical Alarm"
on
The test that checks the
integrity of boot software stored
S1
Yellow
in non-volatile memory failed
because there is a hardware
failure.
The test that checks volatile
S0
Yellow
memory failed because there is
a hardware failure.
Meaning When Lit
Boot Up
"(Optional)
Page
21).
Normal Operation
One or more channels on Base
Station 1 are busy. If flashing, a
software upgrade is in process.
One or more channels on Base
Station 2 are busy.
If flashing, a critical alarm has
occurred.