Step 9: Program Strata Dk - Toshiba Strata AirLink Installation Manual

Digital business telephone systems
Hide thumbs Also See for Strata AirLink:
Table of Contents

Advertisement

RWIU System Installation

Step 9: Program Strata DK

Table 15
Strata DK40i and DK424 PCB and Power Supply PFs (continued)
PCB Type
RMDS
RPTU
RRCS-12
RRCS-4
RRCS-8
RSIS
RSIU
RSSU
RSTU + R48S (-48VDC)
RSTU2
RWIU
Table 16
Example of Strata DK424 Base Cabinet Configuration with RCTUA4A
RCTUA4A
RRCS-4
PDKU2
RCOU + RCOS
RBSU + RBSS
RWIU
Total
Table 17
Example of Strata DK40i Expansion Cabinet Configuration
RCOU + RSOU
RBSU + RBSS
RWIU
Total
Step 9: Program Strata DK
Important!
1. Determine how many handsets, PDKU ports, and available slots are required before
programming the Strata DK. Up to 32 handsets per RWIU are allowed.
2. Use the following programs:
o
Program 03 for Code 61 (slot assignments).
o
Program 32 for Auto Preference.
o
Program 39 for flexible button assignments.
50
+5VDC PF
0.35
2.6
1.5
0.4
1.0
0.35
1.0
0.7
1.4
4.0
9.2
PCB
Quantity
PCB
Quantity
Do not use a DKT that has an intercom button for Speed Dial programming.
-24VDC PF
0.16
1.0
1.0
0.3
0.5
0.15
0.3
0.3
1.0
2.3
0.0
+5VDC PF
1
2.0
1
0.4
2
1.6
1
3.6
1
3.2
1
9.0
7
19.8
+5VDC PF
1
3.6
1
3.2
2
18.0
4
24.8
Strata AirLink Installation Guide
Notes
2400 bps MODEM.
With 8 SLTs.
With 8 MWs.
With 8, 16, 24, or 32 handsets.
-24VDC PF
1.0
0.3
0.3
4.0 (8 COs)
0.3
0.0
5.9
-24VDC PF
4.0 (8 COs)
0.3
0.0
4.3
5/00