BSIA System Installation
BSIA Additional Information
BSIA Additional Information
The following tables have additional information unique to the BSIA system and cover:
o
BSIA (controller) specifications –
o
Adapter and BSIA pinouts –
o
ALM removal
Initial configuration change
o
o
Password change
o
Base Station additions
o
Communication port change
BSIA (Controller) Specifications
Table 8
BSIA Specifications
Dimensions
Weight
Mount
Input Power
Temperatures
Altitude
Adapter and BSIA Pinouts
Tables 9
Table 9
DB9 and DB25 Adapter Pinouts
8-Pin Jack
1/BLU
2/ORG
3/BLK
4/RED
38
Tables 9
Name
and
10
list the adapter and BSIA pinouts.
DB9-F
DB25-F
Not Used
Not Used
7
4
8
5
2
3
Table 8
and
10
Description
16.84 x 9.29 x 1.75 inches
4.6 lbs. without ALM
Wall or industry-standard rack mount
-48VDC or 110/220VAC with optional power supply
Operating: 10°~40°C
Storage: -20°~53°C
Operating Humidity: 20 to 80% non-condensing
Storage Humidity: 5 to 95% non-condensing
Operating: 4,920 ft.
Note Systems operating above 4,920 ft. in low humidity areas
could require additional cooling.
Storage: 940 to 9,400 ft.
8-Pin Jack
5/GRN
6/YEL
7/BRN
8/WHT
DB9-F
DB25-F
3
2
5
7
Not Used
Not Used
Not Used
Not Used
Strata AirLink Installation Guide
5/00