Toshiba Strata AirLink Installation Manual page 97

Digital business telephone systems
Hide thumbs Also See for Strata AirLink:
Table of Contents

Advertisement

4. Disconnect the BSIA from power.
5. Disconnect the 25-pair cables from P1 and P2 on the BSIA.
6. Disconnect the transmit and receive cables from the Base Station and connect them into each
end of the RJ-11 line adapter.
7. Set the multimeter to the ohms scale.
8. To check the distance to Base Station 1, connect the multimeter probes between pins 20 and 46
of the 25-pair cable that connects to P1 on the BSIA. If no reading or a high resistance is
reported, measure between pins 20 and 21. A reading should register at only one of the pairs
and must be less than the values listed in
Table 28
Cable DC Resistance
Input
Power
Line
Local
9. Based on which pins returned a valid reading in
pairs:
o
Valid reading pins 20/46 – measure pins 21/45
o
Valid reading pins 20/21 – measure pins 45/46
The readings between the measured sets of pins should be similar.
10. To check the distance to Base Station 2, connect the multimeter probes between pins 24 and
50. If no reading or a high resistance is reported, measure between pins 24 and 25.
Note
A reading should register at only one of the pairs and must be less than the values listed in
Table
28.
11. Based on which pins returned a valid reading in
pairs:
o
Valid reading pins 24/50 – measure pins 25/49
Valid reading pins 24/25 – measure pins 49/50
o
The readings between the measured sets of pins should be similar.
12. If the multimeter reports no reading or high resistance, check the readings between any of the
other pins specified in
If readings after performing
reversed or shorted somewhere in the installation. If not, there are open connections
somewhere in the installation; check and correct all punch-down connections and repeat
8~11.
Strata AirLink Installation Guide
Table
Wire
Gauge
22, 24, or mixed
22
24
Steps
8~11.
Step 9
are correct, the transmit and receive pairs are probably
5/00
Maintenance and Troubleshooting
28.
Maximum DC Resistance
Allowed for 2,000 feet
98 ohms
66 ohms
104 ohms
Step
8, check readings between the following
Step
10, check readings between the following
Troubleshooting
Steps
87