(6) Detaching and refitting the paper conveying unit

Follow the procedure below to maintenance of the paper feed section.
Procedure
1. Remove the drum unit (see page 1-6-38).
2. Remove the stop ring and strap from the rear side. Restore the paper conveying unit. Remove the pin and
plate, and then remove the stopper from the front side.
Stop ring
Strap
3. Open the left cover until it is put horizontally.
4. Push the fitting portions of the fixtures
located on the front and rear and then
remove the fixtures from the left cover.
5. Remove the left cover from the MFP.
Left cover
Figure 1-6-17
Plate
Stopper
Pin
Fixture
Left cover
Figure 1-6-18
2DA/2DB-3.0
Fixture
1-6-11