Kyocera KM-1650 Service Manual page 84

Hide thumbs Also See for KM-1650:
Table of Contents

Advertisement

Maintenance
item No.
Adjusting the shading position
U063
Description
Changes the shading position.
Purpose
Used when white lines continue to appear longitudinally on the image after the shading plate is cleaned. This
is due to flaws or stains inside the shading plate. To prevent this problem, the shading position should be
changed so that shading is possible without being affected by the flaws or stains.
Method
1. Press the start key. The screen for setting is displayed.
2. Change the setting using the left/right cursor keys.
Description
Shading position
Increasing the setting moves the shading position toward the machine right, and decreasing it moves
the position toward the machine left.
3. Press the start key. The value is set.
Interrupt copy mode
While this maintenance item is being performed, copying from an original can be made in interrupt copy
mode.
1. Press the interrupt key. The machine enters the interrupt copy mode.
2. Set the original and press the strat key.
To return to the screen for setting, press the interrupt key.
Completion
Press the stop/clear key at the screen for setting. The screen for selecting a maintenance item No. is dis-
played.
Adjusting the scanner magnification
U065
Adjustment
See pages 1-6-33 and 34.
Adjusting the leading edge registration for scanning an original on the contact glass
U066
Adjustment
See page 1-6-35.
Adjusting the center line for scanning an original on the contact glass
U067
Adjustment
See page 1-6-36.
Adjusting the scanning position for originals from the DP
U068
Description
Adjusts the position for scanning originals from the DP.
Purpose
Used when there is a regular error between the leading edges of the original and the copy image when the DP
is used.
Method
Press the start key. The screen for setting is displayed.
Setting
1. Change the setting using the left/right cursor keys.
Description
Scanning position
Increasing the setting moves the image backward, and decreasing it moves the image forward.
2. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Description
Setting range
Initial setting
-8 to +8
0
Setting range
Initial setting
-17 to +17
0
Change in value per step
0.17 mm
Change in value per step
0.17 mm
2DA/2DB-1
1-4-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-2050

Table of Contents