2-1. Replacing the CCD Unit

n
Do not replace the CCD unit with the power
turned on.
Before replacing the CCD unit, be sure to turn off
the power switch and disconnect the TRIAX cable
or the cable connected to the DC IN connector.
1. Remove the inside panel and open the outside
panel. (Refer to Section 1-4.)
2. Disconnect the fl exible card wires from the
connectors CN1 and CN3 on the TG-265
board.
n
Be careful not to bend the fl exible card wire.
This shortens the wire life.
3. Remove the four screws to remove the front
assembly.
4. Loosen the setscrew to detach the fi lter select
knob.
n
Attach the fi lter select knob using the follow-
ing steps.
(1) Turn the knob shaft to a position where
the fi lter with the lightest color (1: clear)
appears when viewed from the lens
mount section.
(2) Match the fi lter select knob number 1
with the mark on the front panel, and
secure the knob with a setscrew.
5. Remove the four hexagon cap screws and the
four spring washers to detach the front panel.
HXC-100/V1 (E)
Section 2

Replacement of Main Parts

TG-265 board
Front assembly
B3 x 10
B3 x 10
Filter select knob
HEXAGON 2 x 3
CN1
CN3
Setscrew
Knob shaft
Front panel
SW3
Filter with the
lightest color
(1: clear)
Mark
2-1