1-12-2. Periodic Replacement Parts
This table does not describe the guarantee period of part.
The replacement period of each part depends on the environment and condition.
Refer to "Section 2 Replacement of Main Parts" for the replacement method of parts.
Part name
FAN, DC (40 SQUARE)
*: When used for eight hours a day.
1-12-3. Cleaning the Air Vents
Clogging of dust or foreign matters may cause a temperature increase inside the camera, which may result
in a failure.
Clean the air vents every two or three months.
1. Loosen the two screws with stopper, and remove the
shoulder pad assembly.
2. Remove dust on the three air vent areas with a vacuum
cleaner.
1-13. Description of CCD Block Number
Every CCD unit has its own ID number called CCD block number. It shows the CCD block type and
serial number of the CCD block.
The CCD block number label is attached inside the CCD unit.
For replacing the CCD unit, refer to Section 2-1.
1-32
Sony Part No.
! 1-787-847-11
Check/replacement period
Replace every two years
*
Air vents
Shoulder pad assembly
Air vent
Screws with stopper
HXC-100/V1 (E)