Electrical Alignment; Preparations; Equipment Required; Precautions On Adjustments - Sony HXC-100 Service Manual

Hd color camera
Hide thumbs Also See for HXC-100:
Table of Contents

Advertisement

When any board of this unit is repaired or replaced, perform electrical adjustments as follows.
m
. Perform the video system level adjustment (Section 3-4) according to customer needs.
. Master setup unit MSU-900 and other equipment/tools are used for electrical adjustments of the unit.
Refer to Section 3-1-8 when using the camera setup menu for electrical adjustments without using
MSU-900.

3-1. Preparations

3-1-1. Equipment Required

Measuring equipment
. HDTV serial digital waveform monitor: Leader Electronics LV5150DA, Leader Electronics LV5152DA
. HD color monitor:
Sony BVM-D20F1/BVM-D14H5 or equivalent
. Oscilloscope:
Tektronix TDS460A or equivalent
. Frequency counter
. FM signal generator: ROHDE & SCHWARS SMHU58 or equivalent
. Audio analyzer
Related equipment
. HDVS camera system: MSU-900/950, HDVF-200/550
. Lens:
Canon HJ18 or equivalent
. CCU:
HXCU-100
Tools
. Pattern box PTB-500:
. Grayscale chart (16 : 9 transparent type): Sony Part No.: J-6394-080-A
. Grayscale chart (4 : 3 refl ective type):

3-1-2. Precautions on Adjustments

. Turn on the external main power switch before starting adjustments, and warm up the unit for about 10
minutes.
. All measuring equipment must have been calibrated.
. Periodic maintenance must have been conducted for the pattern box.
. "Section 3-1-7 Initial Settings" must have been completed.
HXC-100/V1 (E)
Section 3

Electrical Alignment

(multi format) or equivalent
Sony Part No.: J-6029-140-B
Commercially available
3-1

Hide quick links:

Advertisement

Table of Contents
loading