1-8-3. Adjustment and Settings when Replacing SY-363 Board

Camera settings and various fi les are stored on the SY-363 board. When the SY-363 board is replaced, the
contents of the reference fi le, scene fi le, lens fi le, and operator fi le are lost. Store these fi les in a Memory
Stick or other storage media beforehand, and then replace the SY-363 board.
Since the OHB fi le is stored in the CCD unit, it is not lost by the replacement of the board.
Replacement
1. Store the reference fi le, scene fi le, and operator fi le in a Memory Stick.
. Reference fi le (Refer to Section 4-5.)
. Scene fi le (Refer to Section 4-4.)
. Operator fi le (Refer to Section 4-2.)
2. Replace the SY-363 board. (Refer to Section 2-8-18.)
3. Install the latest fi rmware version. (Refer to Section 1-10.)
4. Execute REFERENCE (ALL) on the FILE CLEAR page of the FILE menu. (Refer to Section 4-5.)
5. Execute STORE FILE on the REFERENCE page of the FILE menu. (Refer to Section 4-5.)
n
If ALL PRESET is not executed, the intercom panel may not work correctly.
6. Execute "3-2. Automatic Adjustment."
7. Execute "3-4. Video System Level Adjustment."
8. Read the stored reference fi le, scene fi le, and operator fi le.
. Reference fi le (Refer to Section 4-5.)
. Scene fi le (Refer to Section 4-4.)
. Operator fi le (Refer to Section 4-2.)
9. Adjust the lens fi le data. (Refer to Section 4-6.)
10. Execute AUTO LEVEL on the AUTO SETUP page of the MAINTENANCE menu. (Refer to Section
4-5.)