Overview Of The Field Setting On The Outdoor Units; Setting Contents And Code No. For Outdoor Units - Daikin SkyAir GQI-Eco Series Service Manual

Skyair gqi-eco rzqg71~140lv1b series heat pump r-410a 50hz
Table of Contents

Advertisement

Field Setting from Remote Controller
2.4

Overview of the Field Setting on the Outdoor Units

Remote
The table below contains the remote controller settings.
controller
settings
Mode
First
Description
No.
Code
No.
0
Night time low
noise operation
1
Automatic low
noise start and
16 (26)
stop time
2
EDP room
setting
3
Defrost starting
setting
Jumpers
The table below contains the jumper field settings.
Jumper
Label on PCB
(A1P)
JX5
JX5
Factory settings
The table below contains the factory settings of all outdoor units
62
Second Code No.
01
Disabled
Automatic
(Factory
low noise
setting)
activation
Disabled
(Factory
setting)
Standard
Defrost
(Factory
slow
setting)
starting
setting
Function
Set as Cooling Only, For RZQG71·100LV1B
Mode No.
First Code No.
0
1
26
2
3
02
03
Capacity
Automatic
preceding
low noise +
setting
capacity
(when
preceding
using
KRP58
option)
22h00 ~
22h00 ~
06h00
08h00
(Factory)
EDP room
EDP room
setting
setting +
no freeze
up
Defrost
quick
starting
setting
SiBE281013
Details
04
05
Refer to
P63.
20h00 ~
Refer to
08h00
P63.
Refer to
P66.
Refer to
P70.
Details
For RZQG125·140LV1B,
use the other PCB set as
Cooling Only (no JX5)
Second Code No.
01
04
01
01
Field Setting