Option 32: Supervisory Time; Option 33: Modem Sensitivity; Option 34: Vox Mic Gain; Option 35: Vox Gain Range - GE CareGard Installation Instructions Manual

Security system
Hide thumbs Also See for CareGard:
Table of Contents

Advertisement

Option 32: Supervisory Time

The Supervisory Time option controls the report time of supervisory condi-
tions to the central monitoring station — conditions include: sensor failure;
system low-battery; sensor low-battery; and automatic phone test.
In addition, when the panel's Auto Phone Test (Option 14) is enabled, a
phone test is performed at the programmed, supervisory time.
Note
All medication reminders are reported at supervisory time if Report Medication
Failure (Option 40) is set to 1.

Option 33: Modem Sensitivity

When the Modem Sensitivity option is set to ON, modem sensitivity is
high; when the option is set to OFF, sensitivity is normal.
Note
The Modem Sensitivity option should be used only when the panel experiences
excessive problems reporting to the central monitoring station.

Option 34: VOX Mic Gain

The VOX Mic Gain option sets mic gain (sensitivity) during a two-way
audio session. The mic gain setting is affected by room size and acoustics.
The mic gain settings range from 01 (low) to 64 (high) and must include two
digits.

Option 35: VOX Gain Range

The VOX Gain Range option sets the gain range for a voice-activated
switch. The VOX gain settings range from 01 (low) to 64 (high) and must
include two digits.
• For maximum results, VOX Gain Range should be set equal to or greater
than the setting for VOX Mic Gain (Option 34).

Option 36: Manual Mic Gain

The Manual Mic Gain option sets mic gain (sensitivity) during a two-way
audio session. The manual mic gain is affected by room size and acoustics.
Manual mic gain settings range from 01 (low) to 64 (high) must include two
digits.

Option 37: VOX Receiver Gain

The VOX Receiver Gain option sets receiver gain during two-way audio
sessions. If the VOX switch activates the speaker and the central monitoring
station is not trying to communicate, decrease settings for Option 34 and
Option 37.
If the VOX switch does not activate the speaker when the monitoring station
is trying to communicate, increase the Option 37 setting and decrease the
Option 34 setting.
The receiver gain settings range from 01 to 64 and must include two digits.
VOX Receiver Gain settings do not effect speaker volume.
17
Range = Any Time (Default = 12:00
¾
To program Supervisory Time:
1. Press Add.
2. Press Option #.
3. Press 3, then 2.
4. Enter the desired Supervisory Time by
pressing Hours (+/–) and Minutes (+/–).
5. Press Done.
Range = On/Off (Default = Off)
¾
To program Modem Sensitivity:
1. Press Add or Delete.
2. Press Option #.
3. Press 3, then 3 again.
4. Press Done.
Range = 01-64 (Default = 14)
¾
To program VOX Mic Gain:
1. Press Add.
2. Press Option #.
3. Press 3, then 4.
4. Enter the VOX Mic Gain setting.
5. Press Done.
Range = 01-64 (Default = 20)
¾
To program VOX Gain Range:
1. Press Add.
2. Press Option #.
3. Press 3, then 5.
4. Enter the VOX Gain Range setting.
5. Press Done.
Range = 01-64 (Default = 32)
¾
To program Manual Mic Gain:
1. Press Add.
2. Press Option #.
3. Press 3, then 6.
4. Enter the Manual Mic Gain setting.
5. Press Done.
Range = 01-64 (Default = 06)
¾
To program VOX Receiver Gain:
1. Press Add.
2. Press Option #.
3. Press 3, then 7.
4. Enter the VOX Receiver Gain setting.
5. Press Done.
Programming Options
.
.)