Setting The Clock; Setting An Access Code; Utility Access Code 1 (Dealer Code) - GE CareGard Installation Instructions Manual

Security system
Hide thumbs Also See for CareGard:
Table of Contents

Advertisement

Programming

Setting the Clock

You can set the panel clock after you have entered Program Mode.
¾
To set the clock:
1. Open panel cover and enter Utility Access Code 1.
2. Press Clock Set.
3. Press Hours (+) and (–). Stop when the panel announces the correct hour.
4. Press Minutes (+) and (–). Stop when the panel announces the correct minutes.
5. Press Done. The panel announces the set time.

Setting an Access Code

There are three codes you can use to enter Program Mode — Utility Access Code 1, Utility
Access Code 2, and Master Access Code.
In addition, the panel also recognizes five codes that support Option 51. These five codes can be
programmed only by a dealer or installer and include Access Codes 1, 2, 3, 4, and 5. The length
of any code must match the setting established for Access Code Length (Option 28).
Prior to entering the panel's Program Mode, you must open the panel cover and place the
Installer Template (see Figure 4) over the existing panel menu.
The Installer Template provides you with the necessary instructions for adding, changing, and
deleting access codes and panel options. You can remove the Installer Template after you have
completed all programming functions.
I N S T R U C T I O N S
Add Option
Option #1:
Panel Voice Enable
Option #2:
Account No.
Option #3:
Phone No.
See Note
Press
and follow
Add
Option #
voice prompts.
Add Access Code
See Note
Press
Add
Access Code
use red numbers to enter access code.
Set Clock
Press
Clock Set
Hours
Delete
To delete an option or access code
press
and follow voice prompts.
Delete
Cancel
If you make a mistake or want to start
over press
Cancel

Utility Access Code 1 (Dealer Code)

The default value for Utility Access Code 1 can be set to 654321, 54321, 4321 (factory default),
or 321. When initiated, the code allows you to program all access codes and panel options; in
addition, the code is also used to lock the primary phone number into panel memory.
¾
To set Utility Access Code 1:
1. Open panel cover and enter 4321 (default setting).
2. Press Add.
3. Press Access Code until the panel announces "Utility Access Code One. Press again for next
access code or DONE to select."
4. Press Done.
5. Enter the selected code. The panel announces each number after it is entered.
START MENU
Clock Set
1
2
Add
, then
DONE
3
Delete
See Note
4
Access Code
Minutes
DONE
*
5
Sensor
MAIN MENU
*
Option #
*
Press for program information.
Figure 4. Installer Template
+
6
+
Hours
-
Minutes
7
-
8
DONE
9
Cancel
0
Note:
Hold key or press repeatedly
until you hear the desired item.
6

Advertisement

Table of Contents
loading

Table of Contents