Output Bin Sensor Test
Use this test to determine whether or not the output bin sensors are working correctly. To
run the test, select the Sensor Test operation from the OUTPUT BIN TESTS menu.
The following sensors will be listed in the bottom level menu:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
To select one of the sensor above, Press either Menu> or Menu< until the desired sensor
displays. Press Select for that sensor.
Once the screen displays, you can manually actuate the sensor. When the sensor is
closed, CL displays. Likewise, when the sensor is open, OP displays. If the wrong
message displays, the sensor may be malfunctioning.
To exit the sensor test, press Return
3-18
Service Manual
Output Bin1
Output Bin 2
Output Bin 3
Output Bin 4
Output Bin 5
Output Bin 6
Output Bin 7
Output Bin 8
Output Bin 9
Output Bin 10
Vertical Sensor
Bin 10 Jam Sensor
MBX In Sensor
Door Interlock
4025-XXX