Output Bin Sensor Test
This test verifies if the any of the output bin sensors are working correctly.
The following Output options, if installed, are supported by this test.
Standard Bin
Output Expander
High Capacity Output Stacker
5-Bin Mailbox
To run the Output Bin Sensor Test:
1.
Select Output Bin Sensor Test from the menu.
2.
Select the Bin you want to test.
–
If Standard Bin is selected the following is displayed.
Standard Bin
F=OP
F=Standard Bin Output Bin Full Sensor
–
If Output Expander is selected the following is displayed.
<output bin>
P=OP F=OP NF=OP
P=Output Expander Pass Thru Sensor.
F=Output Expander Full Sensor
NF=Output Expander Near Full Sensor.
–
If High Capacity Output Stacker is selected the following is displayed.
HC Bin 1
TP=OP
P=OP F=OP NF=OP
TP=High Capacity Output Stacker top position sensor.
P=High Capacity Output Stacker Pass Thru Sensor.
F=High Capacity Output Stacker Full Sensor.
NF=High Capacity Output Stacker Near Full Sensor.
–
If 5-Bin Mailbox is selected the following is displayed.
<output bin>
P1=OP P2=OP L=NL
P1=5-Bin Mailbox first Pass Thru Sensor.
P2=5-Bin Mailbox second Pass Thru Sensor.
L=5-Bin Mailbox output level sensor where:
L=EM indicates the bin is empty.
L=NL indicates the bin contains media but the bin is not near full nor full.
L=NF indicates the bin is near full.
L=FL indicates the bin is full.
3.
Once the screen is displayed you can manually actuate the sensor you want to test.
When the sensor is closed (CL) displays, and when the sensor is open (OP)
displays.
4.
To exit the test press Return or Stop.
5060-XXX
3-11
Diagnostic Aids