Canon iR2200 Service Handbook page 267

Hide thumbs Also See for iR2200:
Table of Contents

Advertisement

E805
The clock signal is absent for 5 sec or more after the fan drive signal has
been generated. The detail codes of the fans in question are as follows:
0001
developing fan (FM1)
0002
fixing fan (FM2)
0003
curl reducing fan (FM4)
0004
curl reducing fan (FM5)
0005
electrical unit fan (FM3)
Main cause
The fan wiring is faulty (short circuit, open circuit). The fan is faulty. The
DC controller PCB is faulty.
Action
1. Foreign matter
Is there foreign matter that prevents the rotation of the fan?
YES: Remove the foreign matter.
2. Wiring, Connector
Are the wiring and connector of the fan normal?
Developing fan (FM1):
Fixing fan (FM2):
Curl reducing fan (FM4):
Curl reducing fan (FM5):
Electrical unit fan (FM3):
NO:
3. Fan, DC controller PCB
Try replacing the fan. Is the problem corrected?
YES: End.
NO:
Correct the wiring and the connection.
Replace the DC controller PCB.
CHAPTER 6 SELF DIAGNOSIS
DC controller PCB (J302B)
DC controller PCB (J308B)
DC controller PCB (J311B)
DC controller PCB (J311B)
main controller PCB (J1028)
6-35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir2800Ir3300

Table of Contents