Canon iR2200 Service Handbook page 236

Hide thumbs Also See for iR2200:
Table of Contents

Advertisement

CHAPTER 6 SELF DIAGNOSIS
E001
0000
The main thermistor detects 250°C or higher.
0001
The main thermistor or the sub thermistor detects overheating (hardware
circuit detection).
0002
The sub thermistor detects about 295°C or higher.
Main cause
The fixing film unit is faulty (i.e., the thermistor has a short circuit). The
main power supply PCB is faulty. The DC controller PCB is faulty.
Caution
To clear the error, execute the following in service move:
COPIER>FUNCTION>CLEAR>ERR.
Action
1. Fixing film unit
Check the interval between pin 1 and pin 2 and between pin 3 and pin 4 of
the connectors (4-pin) of the thermistor for electrical continuity. Is it 0 Ω
(short circuit)?
YES: The thermistor has a short circuit. Replace the fixing film unit.
If the thermistor has a short circuit, the indication in service mode
(COPIER>DISPLAY>ANALOG) will be as follows from the start: FIX-
REF.
C=250°C for the main thermistor; FIX-E=310°C for the sub thermistor.
2. Main power supply PCB, DC controller PCB
Try replacing the main power supply PCB. Is the problem corrected?
YES: End.
NO:
6-4
Replace the DC controller PCB.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir2800Ir3300

Table of Contents