CHAPTER 6 SELF DIAGNOSIS
E032
0001
The DA unit connection is disconnected (after connection).
Main cause
The DA unit is faulty. The main controller PCB is faulty.
Action
1. Connector
Is the DA unit connected securely?
NO:
2. DA controller, Main controller PCB
Try replacing the DA unit. Is the problem corrected?
YES: End.
NO:
6-10
Connect it securely.
Replace the main controller PCB.