3) Thread the edge of the spring [1] that
comes as an attachment so as to fit it
through the catch 1 [2] and then the
catch 2 [3].
4) Holding the bottom (1st and 2nd loops)
of the spring, fit it through the catch 3
[4]; then, thread it until distance A is
about 15 mm from the catch 2 [3].
At this time, check to make sure that the
spring is firmly on the bottom plate.

7.3 Changing the Size

7.3.1 Changing the Size
1) Match the lifter [1] and the side guide
plate [2] against the size positioning line
of the envelope feeder in relation to the
edges of the side guide plate; then, se-
cure them in place by using two mount-
ing screws [3] each.
Take care so that the side guide
plate will not extend beyond the
envelope feeder (as by choosing
the wrong mounting hole). See
the next page for the correct
mounting hole.
CHAPTER 3 STANDARDS AND ADJUSTMENTS
[2]
[1]
[2]
[3]
[4]
F03-702-03
[1]
F03-703-01
[3]
A
[2]
[3]
3-25