ELECTRICAL CONNECTIONS BETWEEN INDOOR AND
OUTDOOR UNITS
1. To connect the indoor unit to the outdoor nit
use the following electrical cables, protected for
outdoor use:
Cooling and heating model:
Multiple wire cable (220-240V, 50Hz).
2
5 wires x 1.5 mm
2
5 wires x 0.5 mm - for low voltage
(supplied with the unit).
Cooling only models:
Multiple wire cable (220-240V, 50Hz)
2
4 wires x 1.5 mm
2. Prepare the multiple wire(7)cable ends for
connection as shown in fig.18.
3. Connect the cable ends to the terminals of
the indoor and outdoor units, as shown in
fig.20.
4. Shape a loop and connect the yellow/green
ground wire (2) to ground terminal screw of
the indoor unit, as shown in fig.20a.
NOTE: For multi split and cooling only units skip
steps 5, 6, 7 and 9.
5. Prepare the twin wire cable end for connection
as shown in fig.19.
6. Disconnect the resistor (5) from the indoor unit
twin wire cable (3) and connect the win wire
cable (6) connector instead.
7. connect the other end of the twin wire cable
(6) to the outdoor unit twin wire terminal (9).
8. Secure the multiple wire power cable with the
cable clamps.
9. Fasten the twin wire cable to the power cable
with cable ties.
Fig.17
1.Terminal
2.Cover 3.Cable tie
1
Fig 17
NOTES:
1. The wire color code can be selected by the
installer.
2. Wires leading to outdoor unit twin wire
terminal (9). must be in a separate twin wire
cable, otherwise the electronic controls will
be subjected to operational malfunctions.
3. For cooling only model, terminal number 5
should not be connected.

MULTIPLE WIRE POWER CABLE

3
4
5
8
6
100
A
Fig.18
A.OUTDOOR
B.INDOOR

TWIN-WIRE LOW VOLTAGE CABLE

9
N
3(N)
4
A
Fig.20
5.Resistor
1.Indoor unit terminal
6.Twin wire calbe
2.Ground wire
7.Multiple wire calbe
3.Indoor twin wire cable
8.Cable clamp
4.Indoor coil
CONTENT
Fig18
Fig19
1
E/F PW
4
COOL
ESF EW
HEAT
RESET
MODE
1
2
3
-
-
-
4
L
N
N
11
5
6
L/F
10
B
8
7
9.Outdoor twin wire terminal
10.Fresh-air connect wire
11.Indoor fresh-air wire
A.OUTDOOR B.INDOOR
250
3
4
5
8
6
40
B
5 6
2
3
5
6
Fig20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents