CONTROL SYSTEM
12.9.4

High pressure protection (excluding RH Group)

Mode: (Auto) Heating
Fan:
Any
Timer: Any
I Feel: On or Off
Control Function
Protect the Compressor from high pressure by switching OFF the OFAN and COMP.
o
ICT [
c]
For all models except WAX
67
66
61
55
52
Any
COMP
Off
Any
OFAN is force
OFAN
Off
Off
ON
OPER
BLINK
LED
Notes:
IFAN, HE1 and HE2 will be activated according to the relevant
Heating Mode Sect.
In case of any malfunction in the relay control circuit, the OCT is also
monitored during heating mode. Whenever OCT reaches 70
a high pressure in the outdoor coil, the COMP will be forced off automatically.
The COMP can be turned on again only after the 3 min COMP ON delay and the
OCT is under 70
12-22
COMP is forced OFF
o
c. The OPER LED will not blink in this case.
Revision Y05-03
CONTENT
For WAX model
COMP is forced OFF
o
c, which indicates