12A.13.
Sleep
Mode:
Temp:
Fan:
Timer:
I Feel:
•
The Sleep mode is activated by using the sleep button on the R/C. In Sleep
Mode, the unit will automatically adjust the SPT to turn up/down the room
temperature (RT) gradually to provide maximum comfort to the user in sleep.
•
Sleep is treated as TIMER function. Therefore, the TIMER LED is activated
similar to TIMER function.
12Α.13.1. SPT adjustment in Sleep Mode
•
In cool, auto cool or dry modes, the SPT adjustment is positive (from 0 to +3
•
In heat or auto heat modes, the SPT adjustment is negative (from 0 to -3
•
In other modes, there is no SPT adjustment.
•
The SPT adjustment is cancelled when the Sleep mode is cancelled.
RT
SPT+3
SPT+2
SPT+1
SPT
SPT-1
SPT-2
SPT-3
Start
1
Sleep
Note: If Off-timer is active, the unit may go to SB before or after 7 hours of sleep
operation.
Service Manual - WNG
Any
Set – desired temperature selected
Any
Interact with Sleep Timer as described in sect 12.2
On or Off
7 Hours Sleep operation
for Normal Sleep Mode
Cool, Dry modes
Heat mode
2
3
4
Revision Y05-03
CONTENT
Unit is turned to SB
5
6
7
8
CONTROL SYSTEM
o
c).
o
c).
after Sleep
Time [Hr]
12a-29