By Remote Control Settings - Electra WNG 7 Service Manual

Wng led/lcd series
Table of Contents

Advertisement

12.14.2

By Remote Control Settings:

a.
b.
c.
STEP 3: MODEL SETTING CONFIRMATION
OPERATION MODE
ST
RC
SH
RH
MODEL
WNG
WMN1
WMN4
WMN2/WHX
WMN3
In this term the step motor will turn to HOME POSITION.
Service Manual - WNG
1: TURNING ON THE POWER.
Turn ON the power, make sure that the unit is in operation.
STEP 2 : ENABLE SELF-TEST MODE
Use the remote control to send the first settings to display / indoor unit
HEAT mode, HIGH IFAN, set temperature to 16 ºC, no I-FEEL Sleep or
any other timer settings are needed.
Cover the IR transmitter components in the remote control so that it will
not transmit the signals to the indoor unit display.
Use the remote control to send the second settings to display / indoor unit
COOL mode, LOW IFAN, no I-FEEL Sleep or any other timer settings.
Uncover the remote control IR transmitter and change the temperature
settings. If the display/indoor unit receive the settings properly the
following steps will start:
The STAND-BY and COOL LEDS will indicate the operation mode as
follows:
STAND-BY LED
Testing the Model configuration. Selected by the COMP, STAND-BY,
TIMER LEDS and FILTER will indicate the model configuration as follows
(the relevant line for this manual is highlighted):
COMP
OPERATE LED
ON
OFF
ON
OFF
OFF
OFF
OFF
Revision Y05-03
CONTENT
ON
OFF
OFF
ON
TIMER LED
OFF
ON
OFF
ON
ON
OFF
ON
ON
CONTROL SYSTEM
COOL LED
OFF
OFF
ON
ON
FILTER LED
OFF
ON
OFF
ON
ON
12-29