12Α.3.3.

List of A/C Groups

The following table defines the different A/C groups, and the applicable operation
modes for each group.
Operating Mode
Fan
Cool
Heat
Dry
Auto Cool/Heat
Notes:
1. Electric heaters do the heating.
2. Heating is done by Compressor (Heat Pump), and by electric heaters.
12A.4.
General functions
12Α.4.1. COMP operation
• For each Mode including POWER OFF & SB, a Min time delay of 3
min before COMP restarting, excluding DEICING Mode.
• The Min operation time of COMP under different operating conditions
is
Heat, Cool, H.P protection or Auto Modes
Fan, Dry, Overflow, Protection modes, or mode change
Service Manual - WNG
ST
Yes
(3)
Yes
(3)
No
(3)
Yes
(3)
No
Operation Mode
Revision Y05-03
CONTENT
RH
RC
SH
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(1)
Yes
Yes
(2)
Yes
Yes
Yes
(1)
(2)
Yes
Yes
Yes
Min operation
time of COMP
CONTROL SYSTEM
3 min.
ignored