12Α.6.6. Heating, RC or SH Group with Auto fan
Mode:
Heat, Auto (at heating)
Temp:
Selected desired temperature
Fan:
Auto
Timer:
Any
I Feel:
On or Off
Sequence Diagram
Maintains room temp at desired level by controlling COMP, IFAN and OFAN.
o
(RT - SPT) [
c]
+2
+1
0
-1
-2
-3
-4
ON
COMP
OFF
(WVL)
ON
HE1
OFF
ON
HE2
OFF
ON
RV
OFF