Serial Commands
Output Format Status
Serial Cmd:
<K743,output format
Default:
0 = Disabled
Options:
0 = Disabled
1 = Enabled
Output Filter Configuration
Filter Number
Serial Cmd:
<K744,filter
decode direction,database index>
Options:
1 to 10
Symbology Type
Serial Cmd: <K744,filter
decode direction,database index>
Default:
0
Options:
0 = Any type
1 = Interleaved 2 of 5
2 = Code 39
3 = Code 128
4 = Codabar
5 = UPC
6 = PDF417
7 = EAN 128
8 = Code 93
9 = Pharmacode
10 = GS1 DataBar (RSS)
11 = MicroPDF417
12 = Composite
Length
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data,
decode direction,database index>
Default:
0
Options:
0 to 128
Wildcard
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data,
decode direction,database index>
*
Default:
= (0x2A)
Options:
Any ASCII input in the form of a pair of hex characters
A-68
status>
number,symbology type,length,wildcard,placeholder,data,
number,symbology