Configuring the Voice Settings
Regional
Cisco SPA100Series Administration Guide
Field
Feature Dial
Services Codes
Description
These codes tell the ATA what to do when the user is
listening to the first or second dial tone.
One or more *codes can be configured into this parameter,
such as *72, or *72|*74|*67|*82, etc. The maximum length is
79 characters. This parameter applies when the user has
a dial tone (first or second dial tone) After receiving dial
tone, a user enters the *code and the target number
according to current dial plan. For example, after user dials
*72, the ATA plays a special tone called a Prompt tone
while awaiting the user to enter a valid target number.
When a complete number is entered, the ATA sends a
INVITE to *72 target_number as in a normal call. This
feature allows the proxy to process features like call
forward (*72) or Block Caller ID (*67)
The *codes should not conflict with any of the other
vertical service codes internally processed by the ATA.
You can remove a corresponding *code that you do not
want to the ATA to process.
You can add a parameter to indicate which tone plays
after the *code is entered, such as *72'c'|*67'p'. Below is a
list of allowed tone parameters (note the use of open
quotes surrounding the parameter, without spaces)
'c' = <Cfwd Dial Tone>
'd' = <Dial Tone>
'm' = <MWI Dial Tone>
'o' = <Outside Dial Tone>
'p' = <Prompt Dial Tone>
's' = <Second Dial Tone>
'x' = No tones are place, x is any digit not used above
If no tone parameter is specified, the ATA plays Prompt
tone by default. If the *code is not to be followed by a
phone number, such as *73 to cancel call forwarding, do
not include this parameter. Instead, add the *code in the
dial plan and the ATA send INVITE *73@..... as usual when
user dials *73.
Default setting: blank