Kyocera Fax System L Service Manual page 92

Optional fax kit
Hide thumbs Also See for Fax System L:
Table of Contents

Advertisement

Connector Pin No.
A1
_WAKEUPFAX
YC1
A2
_FAXSET
Connected
A3
MAIN_RXD
to the main
A4
_FAXREADY
PCB.
A5
_SREQ
A6
_FPVD
A7
FVCLK
A8
_FVSYNC
A9
FMRE
A10
_FPHSYNC
A11
FPVCLK
A12
FAXSLEEP
A13
_MAINSTS
A14
_MMISTS
A15
MAIN_TXD
A16
FMIPOUT
A17
FOVSYNC
A18
_FOHSTHIN
A19
FMREOUT
A20
FFOCLK
B1
PGND
B2
24V
B3
GND
B4
GND
B5
_SETFAX
B6
GND
B7
GND
B8
GND
B9
PFVSYNC
B10
GND
B11
5V
B12
GND
B13
5V
B14
GND
B15
5V
B16
GND
B17
5V
B18
GND
B19
5V
B20
GND
Signal
I/O
O
3.3/0 V DC
I
3.3/0 V DC
O
3.3/0 V DC (pulse)
O
3.3/0 V DC
O
3.3/0 V DC
O
3.3/0 V DC
O
3.3/0 V DC (pulse)
O
3.3/0 V DC
O
3.3/0 V DC
-
-
-
-
I
3.3/0 V DC
I
3.3/0 V DC
I
3.3/0 V DC
I
3.3/0 V DC (pulse)
I
3.3/0 V DC
I
3.3/0 V DC
I
3.3/0 V DC
I
3.3/0 V DC
I
3.3/0 V DC (pulse)
-
-
I
24 V DC
-
-
-
-
O
3.3/0 V DC
-
-
-
-
-
-
-
-
-
-
I
5 V DC
-
-
I
5 V DC
-
-
I
5 V DC
-
-
I
5 V DC
-
-
I
5 V DC
-
-
Voltage
_WAKEUPFAX signal
_FAXSET signal
MAIN_RXD signal
_FAXREADY signal
_SREQ signal
_FPVD signal
FVCLK signal
_FVSYNC signal
FMRE signal
Not used
Not used
FAXSLEEP signal
_MAINSTS signal
_MMISTS signal
MAIN_TXD signal
FMIPOUT signal
FOVSYNC signal
_FOHSTHIN signal
FMREOUT signal
FFOCLK signal
Ground
24 V DC supply
Ground
Ground
_SETFAX signal
Ground
Ground
Ground
Not used
Ground
5 V DC supply
Ground
5 V DC supply
Ground
5 V DC supply
Ground
5 V DC supply
Ground
5 V DC supply
Ground
Description
3JF-1
2-2-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents