Sp7-Xxx: Data Log - Ricoh G112 Service Manual

Hide thumbs Also See for G112:
Table of Contents

Advertisement

PRINTER ENGINE SERVICE MODE [ALL MODELS]

SP7-xxx: Data Log

7001
Operation time
Displays the total number of engine rotation cycles made so far.
NOTE: 1) One cycle is calculated as 3.8 s (G112/G113) of drum rotation.
However, this counter also includes idle rotations.
This counter is not reset at PM.
7003
Total counter
Displays the controller total counter. This counter is used for meter charge,
and it appears when the user presses the Menu key (if meter charge mode is
enabled).
It does not count up when certain items, such as service reports, are printed
(see section 6.6.1. for a complete list of conditions).
7401
SC Counter
Shows the number of SC codes detected.
7502
Total Jam
Shows the total number of paper jams.
7504
Jam location
Displays the number of jams according to the location where jams were
detected.
7504 17 Main 17
7504 18 Main 18
7504 19 Main 19
7504 20 Main 20
7504 21 Main 21
7504 22 Main 22
7504 23 Main 23
7504 24 Main 24
7504 25 Main 25
7504 33 Main 33
7504 34 Main 34
7504 35 Main 35
7504 36 Main 36
7504 49 Main 49
7504 50 Main 50
7504 51 Main 51
7504 52 Main 52
7504 53 Main 53
7504 54 Main 54
7504 255 Main 255
G112/G113/G116/G094/G095/G091
2) One cycle is calculated as 3.0 s (G116) of drum rotation.
PFU (tray 2) paper feed sensor not turned on
PFU (tray 3) paper feed sensor not turned on
Registration sensor not turned on – bypass feed
Registration sensor not turned on –tray 1
Registration sensor not turned on –paper feed unit
Registration sensor not turned on –duplex
Registration sensor not turned off
Paper exit sensor not turned on
Paper exit sensor not turned off
Not used in this machine
Not used in this machine
Not used in this machine
Not used in this machine
Duplex entrance sensor not turned on
Duplex entrance sensor not turned off
Duplex inverter sensor not turned on
Duplex inverter sensor not turned off
Duplex exit sensor not turned on
Duplex exit sensor not turned off
Others
5-20
[0 to 9999 / 0 / 1/step]
[0 to 9999 / 0 / 1 sheet/step]
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

G116G113G091G094G095

Table of Contents