3.7.2 Hot Roller and Fusing Lamp continued
NOTE: 1) Take the gear and the pin off first, before removing the hot roller
from the unit.
2) Use a small screwdriver to separate the guide plate from the unit.
3) Before installing the new hot roller, peel off 3 cm (1 inch) from both
ends of the protective sheet on the new hot roller. Make sure to
remove the rest of the paper before starting the machine.
[E]
[E]: Fusing Lamp ( x 2)
NOTE: The colored cable must be at the hot roller gear side.
[F]: Guide plate (3 hooks)
[G]: Hot roller strippers (1 spring each)
[H]: Hot roller (2 C-rings, 1 gear, 2 bushings)
SM
G094R526.WMF
3-17
G112/G113/G116/G094/G095/G091
FUSING
[H]
[F]
[G]
G094R003.WMF