PRINTER ENGINE SERVICE MODE [ALL MODELS]

SP5-xxx: Mode

5024
mm/inch Display Selection
Selects the unit of measurement.
After selection, turn the main power switch off and on.
5046
ROM Update Disp
5055
[Display IP Address]
5055 1 Displays the LP's IP Address on the display panel. (Default = NO)
5104
A3/11x17 Count
G091
G116
Only
5302
Set Time
Adjusts the RTC (real time clock) time setting. Sets the local time. (Montreal: -
300, Paris: + 60, Beijing: +480, Taipei: +480, Hong Kong: +480)
5305
Auto Off Set
5307
Summer time
5307 1 Setting
5307 3 Rule set (Start)
5307 4 Rule set (End)
5401
U limit auto select
Determines whether the machine adds new user codes in the User
Management Tool in Smart Net Monitor.
5404
[UcodeCtrClr] User Code Counter Clear
5404 1 UcodeCtrClr
G112/G113/G116/G094/G095/G091
0: Europe/Asia (mm), 1: North America (inch)
Enables or disables the ROM Update utility.
When enabled, this utility will be displayed in the
user program mode. DFU
[0 or 1 / 1 / –]
• 0: Enabled
1: Disabled
0: NO, 1: Yes
Specifies whether the counter is doubled for
A3/11" x 17" paper. If "Yes" is selected, the total
counter counts up twice when A3/11" x 17" paper
is used.
Yes
(double count)
[-1440 ∼ 1440 /Montreal: -300/1 minute/step]
DFU
Switches energy saver mode on/off
Enable, Disable
Enable: Energy saver mode will be used
Disable: Energy saver mode will be ignored
Enables or disables the summer time mode.
[0 to 1 / 0 / -] Alphanumeric
0: Off, 1: On
Specifies the start of the daylight saving time.
Specifies the end of the daylight saving time
Yes, No
Clears all counters for users.
5-8
Rev. 10/2005
No
(single count)