Forced (Verified)
When set for this option the user must enter an account code for all outgoing calls. The account code
entered will be verified from a system list of 500 entries. Forced (Verified) codes can contain the digits
0–9.
Forced (Not Verified)
When set for this option, the user must enter an account code for all outgoing calls, but the account
code is not verified against the system list. Non-verified account codes can contain the digits 0–9,
and #.
Voluntary
In this case, account codes are not required to make outgoing calls but may be used if desired. This is
also the method used to assign an account code to incoming calls. These account codes can contain
the digits 0–9 and #.
Account Code Key
The account code (ACCT) key can be programmed on any keyset and will appear as a soft
key on display keysets. This key allows the user to enter account codes without interrupting a
call.
Account Code Key—One Touch
The account code (ACCT) key can be programmed on any keyset. This key can be pro-
grammed with an extender and operates in three different ways, depending on the extender,
as follows.
Extender = 000 When programmed with an extender of 000, pressing the key prompts the user to
enter an account code without interrupting a call.
Extender = 001–999 When programmed with an extender ranging from 001 to 999, pressing the key
will automatically insert the account code entered for that number. This is known as One-Touch ac-
count codes. This option can be denied in system programming to prevent users from bypassing the
security of system account codes.
No Extender When programmed without an extender, pressing the key will prompt the user to enter
the number in the system account code table where the account code is stored.
All Call Voice Page
Users can page all internal and external paging zones at the same time by dialling the All
Page code. Keysets may be restricted from making or receiving pages in system program-
ming. A maximum of 40 keysets can be programmed in each internal page zone to receive
page announcements.
Attention Tone
To get users' attention, a brief tone precedes all page announcements and internal voice
calls. There are separate programmable duration timers for page and voice announce tones.