4.26 Fluorescent Lamp

4
4.26 Fluorescent Lamp
This system uses LCD modules from the following suppliers. The procedure for replacing the
fluorescent lamp is different for each LCD module. Refer to the appropriate procedure.
Type
14.1-inch (XGA)
14.1-inch (SXGA+)
NOTE: - When working with a LCD module, always use a flat, grounded table.
- Handle the backlight unit in the environment without dust, such as on the clean
bench. Keep the worktable free from any screws or other material that may
scratch the LCD surface.
- Use an anti-static or protective sheet.
- When replacing the FL unit, cover with a finger protector or similar to prevent
soiling or scratching the LCD panel.
- Be careful when handling the lamp. Excessive force may break the lamp.
- Be careful not to soil or deform the lamp reflector.
- Make sure that the power of the LCD module is turned off before connecting
or disconnecting cables and connectors.
TECRA M3 Maintenance Manual (960-507)
Part No.
G33C0001P110
Samsung
G33C00025110
TMD
G33C00022110
Samsung
4 Replacement Procedure
Supplier
Section
4.26.1
4.26.2
4.26.3
4-85