Checking The Charging Voltage; Changing The Main Fuse - KTM 690 Enduro EU 2008 Repair Manual

Hide thumbs Also See for 690 Enduro EU 2008:
Table of Contents

Advertisement

11/WIRING HARNESS, BATTERY

Checking the charging voltage

14.6

Changing the main fuse

14.7
Warning
Fire hazard The electrical system can be overloaded by the use of incorrect fuses.
Use only fuses with the prescribed amperage. Never by-pass or repair fuses.
Info
The main fuse protects all power consumers in the vehicle. It is in the housing of the starter relay next to the battery.
Connect the battery charger to the battery. Switch on the battery charger.
Battery charger (58429074000)
You can also use the battery charger to test rest potential and start potential of the
battery, and to test the alternator. With this device, you cannot overcharge the bat-
tery.
Info
Never remove lid
Charge the battery with a maximum of 10% of the capacity specified on the
battery housing
Switch off and disconnect the charger after charging.
Guideline
The charge current, charge voltage and charge time must not be exceeded.
Charge the battery regularly when the
motorcycle is not in use
Install the battery. (
100151-10
Condition
The battery must be fully functional and completely charged.
Remove the seat. (
Remove screws
Push the retaining bracket forward and take off the terminal cover.
Start the motorcycle to make checks. (
302035-10
Measure the voltage between the specified points.
Measuring point Plus (+) – Measuring point Ground (−)
Charging voltage
5,000 rpm
»
If the displayed value is less than the specified value:
Check the plug-in connections from the alternator to the voltage regulator.
Check the plug-in connections from the voltage regulator to the wiring har-
ness.
601014-10
Check the stator winding of the alternator. (
»
If the displayed value is greater than the specified value:
Change the voltage regulator.
.
.
3 months
p. 72)
p. 58)
.
p. 11)
13.5... 15.0 V