IMPORTANT SAFETY PRECAUTIONS
FCC Regulatory Safety Notice - The MobileTouch wireless control panel device has been
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This device generates, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the party responsible for FCC compliance could
void the user's authority to operate the equipment.
General Installation Information
1. All work must be performed by a licensed electrician, and must conform to all national, state,
and local codes.
2. Install to provide drainage of compartment for electrical components.
3. If this system is used to control underwater lighting fixtures, a ground-fault interrupter
(GFCI) must be provided for these fixtures. Conductors on the load side of the ground-fault
circuit-interrupter shall not occupy conduit, junction boxes or enclosures containing other
conductors unless such conductors are also protected by a ground-fault circuit-interrupter.
Refer to local codes for details.
4. A terminal bar stamped
electric shock, this terminal must be connected to the grounding means provided in the
electric supply service panel with a continuous copper wire equivalent in size to the circuit
conductors supplying this equipment (no smaller than 12 AWG or 3.3 mm). The bonding
lug(s) provided on this unit are intended to connect a minimum of one No. 8 AWG for US
installation and two No. 6 AWG for Canadian installations solid copper conductor between
this unit and any metal equipment, metal enclosures or electrical equipment, metal water
pipe, or conduit within 5 feet (1.5 m) of the unit.
5. The electrical supply for this product must include a suitably rated switch or circuit breaker
to open all ungrounded supply conductors to comply with Section 422-20 of the National
Electrical Code, ANSI/NFPA 70.1987. The disconnecting means must be readily accessible
to the tub occupant but installed at least 10 ft. (3.05 m) from the inside wall of the pool.
6. Supply conductor must be sized to support all loads. Maximum supply conductor current
must be 125 Amps at 125 VAC or 63 Amps at 240 VAC.
IntelliTouch Personality Kit Installation Guide
is located inside the supply terminal box. To reduce the risk of
(Continued)