High Voltage Connections; Power Center And Load Center Description; Power Center (Without Sub-Panel) - Intellitouch Pool and Spa Control System Installation Manual

Pool and spa control system personality kit
Hide thumbs Also See for Pool and Spa Control System:
Table of Contents

Advertisement

14

High Voltage Connections

WARNING - It is required that the main power into the home be switched OFF at the main circuit
breaker box whenever the high voltage cover-panel is removed. The main power must also be
switched OFF to access the Power/Load Center enclosure low voltage raceway.

Power Center and Load Center Description

Power Center and Load Center enclosures are identical with the exception of the circuit breaker
base (Sub-panel). For details, refer to the Load Center illustration, see page 15. Not shown is the
high voltage cover-panel and the front door. See the WARNING information above before opening
the cover-panel.

Power Center (without Sub-panel)

The Power Center is connected to an electrical circuit breaker panel (Sub-panel) installed
at the equipment pad. The AC power is provided from the Main-panel (located at the house) to the
Sub-panel. The Power Center is installed next to the Sub-panel. For complete Power/Load Center
installation instructions, refer to the Load/Power Center User's Guide (P/N 520100).
Low voltage
compartment
High voltage
cover panel
attachment
screw holes
Power relays
Auxiliary,
2-Speed Pump
(1-3) or Dimmer
relay locations
Front door
removal screw
Low voltage
raceway
Mounting bracket
IntelliTouch Personality Kit Installation Guide
Power Center Enclosure
(17" H x 17" W x 4.8" D)
Enclosure
Mounting bracket
Low voltage
circuit breakers
System
transformer
Spring latch
Outdoor control
panel attachment
screw holes
Grounding screw
terminals
GFCI knockout
(approved rainproof
cover required)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents