Plumb the solar feed and return lines between the filter and the heater. Install a three-port valve
9
at the feed line. Use a solar valve (model SOL-2T), to allow automatic draining of the panels.
A solar booster pump should be used when the distance to the panels exceed 200 ft., or the
panels are elevated higher than 25 ft.
10
Glazed solar panels require a drain valve (model HW-5B) to allow draining of the panels. This
prevents damage from overheating water. Install a drain valve at the solar feed line and connect
11
to the pool fill line.
Salt Chlorine Generator (SCG): IntelliChlor IC40 or IC20 salt chlorine generator cell with check
12
valve at the heater output. Refer to IntelliChlor User's Guide (P/N 520589) for plumbing
requirements.

Equipment Location

All equipment, with the exception of the Spa-Side remote, must be located at least 10 ft. from the
water's edge.
MobileTouch® wireless remote controller
Recommended Hydraulic Schematic for Shared Equipment System
INTELLICHLOR®
IntelliTouch Personality Kit Installation Guide