Window Removal
See fi gure 20.
1.
Turn the top two spring-loaded window bolts through 90°
to release the window from the fi rebox.
2.
Remove the bottom two spring-loaded window bolts.
3.
Detach the chain from the top right corner of the window.
4.
Carefully lift the window away. Keep the window and
bolts in a safe place.
Ignition Spark Check
See fi gure 21.
The pilot burner and electrode unit are at the left end of the
burner.
Push-in the lighting knob and turn counterclockwise through
the "IGN" position to "PILOT". A spark should fl ash across
from the pilot electrode to the pilot shield.
Figure 21 Ignition spark check
Rear Vent Outlet Positioning
If installing with top vent outlet, ignore this stage.
If installing co-linear venting, see section Co-Linear
Conversion next page.
See fi gure 22.
1.
Remove the rear outlet cover plate and seal by
unscrewing 12 screws. Keep the seal and plate for fi tting
to the top.
2.
Remove the top outer vent collar and seal by unscrewing
12 screws.
3.
Remove the top inner vent collar and seal by unscrewing
8 screws.
4.
Locate the inner collar and seal inside the rear outlet
opening. Secure the inner collar with 8 screws.
5.
Fit the outer collar over inner collar. Loosely fi t the 12
screws. Place the adapter #817VAK or Valor terminal kit
#551DVK over the collars to check alignment. Tighten the
12 screws to secure the outer collar.
6.
Fit the cover plate and seal (removed from the rear) to
the top vent opening with 12 screws.

Appliance Preparation

Figure 20
Figure 22
21