Operating The Fan Controller - BIG ASS FANS Pivot 180 Installation Manual

Table of Contents

Advertisement

Operating the fan controller

WARNING: The following startup procedures apply to standard model controllers. Procedures may vary depending on
installation options and system automation. The installer should verify proper wiring, terminations, and proper voltage
supply before proceeding. High voltage gloves and arc flash protection are recommended.
AUTO
M
Drive Idle/Stopped Screen
AUTO
M
Fan Speed Percentage Display
(73.5% Running FWD)
AUTO
M
Typical Fault Message Display
(Incoming Line Over-Voltage Shown)
Note: The fan should rotate in same direction (counterclockwise when viewed from the floor) during both the warmer and cooler
months. If the fan is not rotating in this direction, press the Direction button, and then press the Memory/Enter button. During the
warmer months, run the fan at higher speeds. This will circulate the air and provide a cooling breeze. During the cooler months, run the
fan at lower speeds. This will push warmer air down from the ceiling to the floor without creating a cooling breeze.
Electrical Installation (cont.)
FWD
RUN
REV
R
F
STOP
FWD
RUN
REV
R
F
STOP
FWD
RUN
REV
R
F
STOP
WWW.BIGASSFANS.COM
PIVOT™ 180
Starting and stopping the fan
The RUN and STOP buttons control the fan start and stop
RUN
functions. To start the fan, press the green RUN button. To stop
the fan, press the red STOP button.
STOP
Adjusting fan speed
The Arrow buttons control speed adjustment. To adjust fan speed,
press the Up or Down Arrow button. Single presses will increase or
decrease the speed in 1-2% increments. Pressing and holding the
Up or Down Arrow button will slowly and continuously adjust fan
speed until the button is released.
Reversing direction of fan rotation
R
F
The direction of fan rotation can be reversed when the fan is
stopped or running. To reverse the direction of rotation, press the
then
Direction button, and then press the Memory/Enter button (as
shown on the left). The associated Direction indicator will flash,
M
indicating the pending change.
©2011 DELTA T CORP.
ALL RIGHTS RESERVED
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents